Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

Manumycin A

  AG-CN2-2000-M005 5 mg


Data Sheet:     SDS:    

CAS
52665-74-4  

Purity
>98% (HPLC)  

MW
550.6  

Shipment
BLUE ICE  

Short Term Storage
+4°C  

Long Term Storage
-20°C  

Shelf Life
Stable for at least 1 year after receipt when stored at -20°C. After reconstitution protect from light at -20°C.  


Description
 
Chemical. CAS: 52665-74-4. Formula: C31H38N2O7. MW: 550.6. Antibiotic. Apoptosis and endoplasmic reticulum stress-mediated cell death inducer. Potent, selective and competitive cell permeable rasfarnesyltransferase inhibitor (IC50 = 30 nM). Does not affect geranylgeranyltransferase (IC50 = 180 µM). Inhibition is competitive with respect to farnesyl pyrophosphate and non-competitive with respect to Ras. Neutral sphingomyelinase inhibitor. Blocks insulin-induced MAP kinase activation in rat cardiac myocytes (19 µM). Targets protein phosphatase 1alpha (PP1alpha) and reduces hydrogen peroxide. Corrects aberrant splicing of the muscle chloride channel Clcn1 in myotonic dystrophy type 1 (DM1). Shows potential anti-inflammatory activity. Irreversible human thioredoxin reductase 1 (TrxR-1) inhibitor (IC50=272nM) and inducer of NADPH oxidase activity. Acts very likely as a Michael acceptor to the nucleophilic Sec residue in the C-terminal redox center of TrxR-1 which yields a SecTRAP (selenium compromised thioredoxin reductase-derived apoptotic proteins), which promotes both apoptosis and necrosis via oxidative stress and increased intracellular reactive oxygen species (ROS) production. Due to the involvement of Ras during exosomes release, manumycin A has been investigated as an inhibitor of exosomes secretion. Acts against myotonic dystrophy type 1 (DM1). Mediates lymphoma apoptosis by targeting protein phosphatase 1alpha.
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g