Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

Anti-Mouse ADAM-9, made in Rat

  REL-103-M213 100 µg

 
Synonyms: Adam9; MDC9; Mltng; AU020942; mKIAA0021
 
ReliaTech
Anti-Mouse ADAM-9, made in Rat


Reactivity
Anti-Mouse  

Applications
WB  

Source / Host
Rat  

Clone
(#7D10)  

IsoType
IgG2  

Shipment
RT  

Long Term Storage
Lyophilized samples are stable for 2 years from date of receipt when stored at -70°C. Reconstituted antibody can be aliquoted and stored frozen at < -20°C for at least six months without detectable loss of activity.  


Description
 
ADAM9, also known as MDC9 or meltrin γ, is a member of the ADAM family that contains a disintegrin and metalloprotease-like domain. Like other membrane-anchored ADAMs, ADAM9 consists of a pro domain with a cysteine switch and furin cleavage sequence, a catalytic domain with the zinc-binding site and Metturn expected for reprolysins, a disintegrin like domain, a cysteine-rich domain, an EGF-like domain, a transmembrane domain, and the cytoplasmic domain. ADAM9 is able to cleave peptides corresponding to cleavage sites of tumor necrosis factorα (TNFα), the p75 TNF receptor, the β-amyloid protein precursor, and the c-kit ligand1, implying that it may participate in shedding of these membrane proteins. In fact, ADAM9 has been shown to shed membrane-anchored heparin-binding EGF-like growth factor. In addition, it also cleaves oxidized insulin B-chain and fibronectin. Besides its catalytic activity, ADAM9 functions as an adhesion molelcule through binding of its disintegrin domain to integrins such as αvβ5 and α6β1. The cytoplasmic domain of ADAM9 interacts with Src homology 3 (SH3)containing proteins and protein kinase C, and may mediate different signaling pathways. ADAM9 is widely expressed in tissues.
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g