Alternative Block ELISA Blocking Buffer

  ICT-6301 1 L

 
 
Immunochemistry Technologies
Alternative Block ELISA Blocking Buffer

Data Sheet:     SDS:    

Concentration
1X  

Long Term Storage
2-8°C  

Shelf Life
Expires two years from date of manufacture  


Description
 
ICT’s Alternative Block ELISA Blocking Buffer provides superior background-blocking performance to eliminate interference and minimize background noise on ELISA formats without the use of conventional cross-reactive protein additives. - Alternative Block is a protein-free, detergent-free ELISA blocking buffer. This unique blocking buffer contains a heterogeneous mixture of proprietary blockers and synthetic stabilizers that block the uncoated regions of the microtiter plate without the use of conventional cross-reactive protein additives or detergents. This buffer is best for most immunoassays, including antibody-sandwich ELISA, competitive assays, and peptide and protein antigen-down ELISA., , Alternative Block’s all-synthetic heterogenous mixture of blocking agents minimizes non-specific binding interactions during the immunoassay process to reduce background noise. Alternative Block provides a microhydrated environment to stabilize the coated protein during long-term storage for improved retention of antigen epitope and antibody binding activity. When preparing batches for storage, an antimicrobial agent allows for stable room temperature blocking and long-term refrigerated storage of dried plates. - 1. Allow product to equilibrate to room temperature (25°C) prior to use., 2. Add 100 µL to each well. When reacting with peroxidase, a soluble blue reaction product develops that can be read at 370 nm or in a range of 620-650 nm. The reaction product is stable for 1 hour., 3. The reaction can be stopped using an appropriate stop solution, such as Stop Solution for TMB Substrates (STOPT), for endpoint assays. STOPT changes the chromogen from blue to yellow and the absorbance to 450 nm. For best results, sample absorbance should be monitored and read before values exceed 2.0 OD units. STOPT can increase the absorbance up to 3-fold, so the reaction should be stopped when absorbance values reach approximately 0.7 OD units.
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g