Applications
IHC, ICC
Long Term Storage
2-8 °C
Description
Peroxidase chromogen-substrate 3-amino-9-ethyl-carbazole (AEC) is an excellent chromogen system that is used in Immunohistochemistry (IHC) and Immunocytochemistry (ICC). - Peroxidase chromogen-substrate 3-amino-9-ethyl-carbazole (AEC) is an excellent chromogen system that is used in Immunohistochemistry (IHC) and Immunocytochemistry (ICC). This chromogen system gives bright red color and is very compatible with hematoxylin nuclear counterstain. This chromogen is soluble in alcohol and organic solvents therefore cannot be mounted with organic mounting medium. We recommend our aqueous mounting medium ImmunoHistoMount (IHM), cat # AR-6503 for mounting of this chromogen. - (THIS KIT CONTAINS approximately 166 X CHROMOGEN, When diluted will make approx. 425 ml))
1. To 5 ml of distilled or deionized water in a test tube, add two drop of reagent B buffer, mix well.
2. Add one drop of reagent C chromogen, mix well.
3. Add one drop of reagent S substrate, mix well. This ready to use reagent is good for several hours. The unused AEC solution can be discarded according to city, county, state, province or country’s regulations.
Application: IHC, ICC
1. After the peroxidase reaction, wash slide with buffer (this buffer should not contain any sodium azide because peroxidase is inactivated), and distilled/ deionized water.
2. Add few drops of ready to use AEC reagent, incubate at RT or 37ºC for 5-10 minutes.
3. Wash 2-5X with buffer, followed by rinsing with distilled/deionized water.
4. Add counterstain compatible with AEC, we use hematoxylin 30-60 seconds (cat. # AR-6521).
5. Wash with tap water, buffer pH 7.4 or higher followed by rinsing with distilled/deionized water.
6. Mount slide with aqueous mounting medium, we use our IHM (cat. # AR-6503) please follow the protocol for mounting medium.
ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).